Delphi Low Pressure Sensors provide precise measurements of operating pressure in two ranges:

  • From -0.54 psig to +0.18 psig (-3.75 kPa to +1.25 kPa gauge)
  • From 0 psig to 2.5 psig (0 kPa to 17.24 kPa gauge)

Delphi Low Pressure Sensors are designed to perform in harsh environments such as extreme temperatures and vibration, thermal and mechanical shock, and chemical contamination.  They provide voltage output proportional to the gauge pressure in low pressure systems.

Benefits

  • Electronic compensation for precise measurements in a variety of environments
  • Reliable and robust:
    • Low part count
    • Automotive grade
    • ISO/TS 16949 certified
  • Mounting flexibility
  • Designed for under-hood environments
  • Appropriate for a wide range of automotive and non-automotive applications
     

Features

  • Patented direct mount, eliminates need for bracket
  • Temperature compensation
  • Electromagnetic interference (EMI) protection
  • All-silicon technology
  • Electronically programmable trim to customer specification
  • Low part count enhances reliability

Typical Applications

Delphi Low Pressure Sensors can be used in fuel vapor and air filter pressure measurement applications.  They can also be used for bladder-type occupant sensing applications in vehicle seating programs.

Delphi Low Pressure Sensors can also be used other non-automotive filtering applications, such as HVAC and fluid-level sensing in home appliances.

Performance Data for Standard Calibration

Pressure Range
Operating -3.75 kPa to 1.25 kPa
Maximum 30 kPa
Full scale accuracy 5%

Temperature Range
Operating -40°C to +80°C
Storage -50°C to +150°C

Electrical Characteristics
Supply voltage 5.0 ± 0.1 VDC
Supply current <10 mADC

Maximum output current

Sink 1 mADC

Source 0.1 mADC

Output impedance <10 Ω
Output voltage 0.5 to 4.5 VDC

Note: Custom calibrations are available upon request.

Delphi Low Pressure Sensor

Delphi Low Pressure Sensors offer compact size to help meet packaging objectives.  Also, they feature a direct mounting capability to eliminate the need for separate mounting brackets.  

Transfer Curve (Er=5.0 V)

Delphi Low Pressure Sensors offer application flexibility, however, a typical sensor voltage output over a low pressure range is shown in this chart.

Allowable Pressure Error

The total output pressure error for Delphi Low Pressure Sensors includes error due to linearity, hysteresis and ratiometricity.

Temperature Error Multiplier


This graph shows the temperature multiplier to the allowable pressure error over the operating temperature range for Delphi Low Pressure Sensors.
 

Performance Advantages

Delphi Low Pressure Sensors feature cutting-edge sensing technology and a patented Delphi Application Specific Integrated Circuit (ASIC) design.  They are built in-house and provide high quality and reliable operation.  Combined with Delphi's vast manufacturing experience, they offer quality and customer satisfaction.

Delphi Low Pressure Sensors are cost-effective and they offer a patented, direct-mount design that can contribute to system savings.  They can be tailored to meet specific customer requirements.

The Delphi Advantage

Delphi has one of the industry's most complete portfolios of sensors and a thorough understanding of systems integration and the entire engine management system.  Delphi offers global manufacturing capabilities for sensors and an in-depth knowledge of regional market requirements.  With more than 25 years' experience in powertrain sensors research and production, Delphi can provide manufacturers with the necessary support and high quality, high-value products tailored to specific customer requirements.

 